Product description: The MEAN WELL IRM series is a range of AC-DC PCB-mount green industrial power modules from 1 W to 90 W, ready to be soldered onto the PCB of electronic instruments or industrial automation equipment;
They accept universal AC input of 85–305 Vac — 80–305 Vac on the IRM-90 — with the IRM-01 to IRM-20 also accepting 120–430 Vdc, and reach efficiency up to 93% in a compact potted case with Class II isolation and built-in EMI filtering;
No-load power consumption is extremely low, below 0.075 W on the IRM-01/02/03, below 0.1 W on the IRM-05 to IRM-30, below 0.15 W on the IRM-45/60 and below 0.3 W on the IRM-90, and the modules comply with BS EN/EN55032 Class B without any additional components;
SMD styles are available for the IRM-02/03 and screw-terminal (ST) styles for the IRM-30/45/60/90, with a –30 to +85 °C operating range (–40 to +85 °C on the IRM-90), overvoltage category II or III, LPS approval on the IRM-05 to IRM-60, and short-circuit, overload and over-voltage protection (plus over temperature on the IRM-90)
The MEAN WELL IRM series is a range of AC-DC PCB-mount green industrial power modules from 1 W to 90 W, ready to be soldered onto the PCB of electronic instruments or industrial automation equipment
They accept universal AC input of 85–305 Vac — 80–305 Vac on the IRM-90 — with the IRM-01 to IRM-20 also accepting 120–430 Vdc, and reach efficiency up to 93% in a compact potted case with Class II isolation and built-in EMI filtering
No-load power consumption is extremely low, below 0.075 W on the IRM-01/02/03, below 0.1 W on the IRM-05 to IRM-30, below 0.15 W on the IRM-45/60 and below 0.3 W on the IRM-90, and the modules comply with BS EN/EN55032 Class B without any additional components
SMD styles are available for the IRM-02/03 and screw-terminal (ST) styles for the IRM-30/45/60/90, with a –30 to +85 °C operating range (–40 to +85 °C on the IRM-90), overvoltage category II or III, LPS approval on the IRM-05 to IRM-60, and short-circuit, overload and over-voltage protection (plus over temperature on the IRM-90)
Product Introduction
The MEAN WELL IRM series is a range of AC-DC PCB-mount green industrial power modules from 1 W to 90 W, ready to be soldered onto the PCB of electronic instruments or industrial automation equipment. They accept universal AC input of 85–305 Vac — 80–305 Vac on the IRM-90 — with the IRM-01 to IRM-20 also accepting 120–430 Vdc, and reach efficiency up to 93% in a compact potted case with Class II isolation and built-in EMI filtering. No-load power consumption is extremely low, below 0.075 W on the IRM-01/02/03, below 0.1 W on the IRM-05 to IRM-30, below 0.15 W on the IRM-45/60 and below 0.3 W on the IRM-90, and the modules comply with BS EN/EN55032 Class B without any additional components. SMD styles are available for the IRM-02/03 and screw-terminal (ST) styles for the IRM-30/45/60/90, with a –30 to +85 °C operating range (–40 to +85 °C on the IRM-90), overvoltage category II or III, LPS approval on the IRM-05 to IRM-60, and short-circuit, overload and over-voltage protection (plus over temperature on the IRM-90). They suit industrial electrical equipment, mechanical equipment, factory automation, handheld electronic devices and industrial control, and carry a 3-year warranty.
IRM-01 to IRM-20 accept 85–305Vac and 120–430Vdc. IRM-30, IRM-45 and IRM-60 accept 85–305Vac. IRM-90 accepts 80–305Vac and 113–431Vdc. All models accept 47–63Hz; IRM-30/45/60 also accept up to 440Hz.
What mounting options does the IRM series offer?
All IRM modules are PCB-mount types that solder directly onto the system PCB. IRM-02 and IRM-03 are also available in an SMD style, and IRM-30, IRM-45, IRM-60 and IRM-90 are also available in a screw-terminal (ST) style for chassis mounting.
What protections are built in?
Short circuit, overload and over voltage protection on all models; IRM-90 also has over temperature protection. Overload protection is hiccup mode, recovering automatically after the fault condition is removed.
What is the peak power of the IRM-90?
IRM-90 provides 100W peak power for 10 seconds — for example, IRM-90-24 delivers 4.13A / 99W peak against 3.75A / 90W continuous (convection). The duty cycle is 33% maximum within every 30 seconds, and the average output power must not exceed the rated power.
A PLC control cabinet looks simple on a wiring diagram: one 24 V DIN-rail supply feeds the PLC, sensors, relays and an HMI. In practice it fails for four reasons — and this case looks at how the MEAN WELL DRP-480-24 answers them.
A small machine control box looks simple on a wiring diagram: one 24V supply feeds a PLC, a handful of sensors and relays, and a small HMI. In practice it fails for five reasons — and this case looks at how the MEAN WELL LRS-350-24 answers them.
A practical guide to sizing a 24V DIN rail supply for PLC and control panels: load and switch-on peak, single-phase vs three-phase input, derating, redundancy (XDR-E N+1) and the XDR / XDR-E / XTR quick-size table.
The MEAN WELL XTR-960-48 (960W, 48V, 20A, three-phase DIN rail) with 200% peak power for modular battery charging, outdoor EV charging and data-centre cooling — key specs and ordering checklist.